The CH-1200A is a high-performance charge amplifier to convert charge signal to voltage signal. Built-in integration function allows optimization of the signal which is input to the vibration data analyzer connected.
Changing into a multi-channel amplifier is easy by connecting multiple units.
- Built-in integration function – Output data can be selected from acceleration, velocity and displacement.
- Filter function – High-pass filter and Low-pass filter remove unwanted vibration and enable more precise measurement.
- Compact, light weight and easily changed to a multi-channel amplifier by connecting units.
Specifications
Maximum Input Charge | ±100000 pC |
Input Connector | Miniature connector |
Charge Condenser | 100 pF, 1000 pF, 10000 pF |
Leak Resistance | 10 GΩ, 1 GΩ, 100 MΩ |
Frequency Response Characteristics | Acceleration: 1.0 Hz to 15 kHz ± 0.5 dB, Velocity: 3.0 Hz to 3 kHz ± 0.5 dB, Displacement: 3.0 Hz to 500 Hz ± 1 dB (However, the frequency at 160 Hz to be 0 dB) |
Accuracy | Acceleration: ± 2 %, Velocity: ± 3 %, Displacement: ± 5 % (at 160 Hz, 25 ℃ ±3 ℃) |
Output Signal (Voltage) | ±10 V |
Maximum Output Load | 3 mA, 1500 pF |
Output Connector | C02 (BNC) |
Input Conversion Noise Level | 0.05 pC (rms) or less |
Output Offset | ±5 mV or less |
Sensitivity | 0.01 to 999 pC/EU |
Filter |
HPF: through, 3 Hz, 10 Hz (-18 dB/oct), LPF: through, 1 kHz, 10 kHz (-18 dB/oct) (10 Hz, 1 kHz are conforming to "Mechanical Vibration of Rotating and Reciprocating Machinery-Requirements for Instruments for Measuring Vibration Severity" |
Maximum Input Alarm Display Function | OFF: [-10 dB/Over] indicator blinks in red when output exceeds ±10 V. The blinks will stop when the output goes within ±10 V. ON: The blinking in red continues unless [▲/RST] switch is pushed when the output exceeds ±10 V. |
Output Sensitivity | Acceleration: 0.01, 0.0316, 0.10, 0.316, 1.00, 3.16, 10.0, 31.6, 100, 316, 1000 mV/EU, Velocity: 0.01, 0.0316, 0.10, 0.316, 1.00, 3.16, 10.0, 31.6, 100, 316, 1000 mV/EU, Displacement: 0.10, 0.316, 1.00, 3.16, 10.0, 31.6, 100, 316, 1000 mV/EU |
Other Function | ·Output level indicator: Turns on in green at -10 dB/F.S., blinks in red at F.S. over. ·Condition memory: The measurement conditions are stored even though the power is OFF. ·Condition lock: Malfunction prevention key |
Power Requirement | 10 V to 15 VDC * AC 100 V: available by AC adapter (sold separately) |
Current Consumption | 120 mA or less (When the value of 1.00 is shown at displayed device) |
Unit Connection | Up to 6 units for one AC adaptor |
Outer Dimensions | 28 (W) × 121 (H) × 194 (D) mm (not included protruded section) |
Weight | Approximately 510 g |
Working Environment | -10℃ to + 50℃, 90 % RH or less (with no condensation) |
Accessories | Joint cable, stabilizer, connecting metal |
Options | PS-P20022C(PE1821078) AC adapter |