CH-1200A

Charge Amplifier

CH-1200A

The CH-1200A is a high-performance charge amplifier to convert charge signal to voltage signal. Built-in integration function allows optimization of the signal which is input to the vibration data analyzer connected.

Changing into a multi-channel amplifier is easy by connecting multiple units.

    •     Built-in integration function – Output data can be selected from acceleration, velocity and displacement.
    •     Filter function – High-pass filter and Low-pass filter remove unwanted vibration and enable more precise measurement.
    •     Compact, light weight and easily changed to a multi-channel amplifier by connecting units.

SEND Inquiry

Specifications

Maximum Input Charge ±100000 pC
Input Connector Miniature connector
Charge Condenser 100 pF, 1000 pF, 10000 pF
Leak Resistance 10 GΩ, 1 GΩ, 100 MΩ
Frequency Response Characteristics Acceleration: 1.0 Hz to 15 kHz ± 0.5 dB, Velocity: 3.0 Hz to 3 kHz ± 0.5 dB, Displacement: 3.0 Hz to 500 Hz ± 1 dB (However, the frequency at 160 Hz to be 0 dB)
Accuracy Acceleration: ± 2 %, Velocity: ± 3 %, Displacement: ± 5 % (at 160 Hz, 25 ℃ ±3 ℃)
Output Signal (Voltage) ±10 V
Maximum Output Load 3 mA, 1500 pF
Output Connector C02 (BNC)
Input Conversion Noise Level 0.05 pC (rms) or less
Output Offset ±5 mV or less
Sensitivity 0.01 to 999 pC/EU
Filter HPF: through, 3 Hz, 10 Hz (-18 dB/oct), LPF: through, 1 kHz, 10 kHz (-18 dB/oct) (10 Hz, 1 kHz are conforming to "Mechanical Vibration of Rotating and Reciprocating Machinery-Requirements for Instruments for Measuring Vibration Severity" )
Maximum Input Alarm Display Function OFF: [-10 dB/Over] indicator blinks in red when output exceeds ±10 V. The blinks will stop when the output goes within ±10 V. ON: The blinking in red continues unless [▲/RST] switch is pushed when the output exceeds ±10 V.
Output Sensitivity Acceleration: 0.01, 0.0316, 0.10, 0.316, 1.00, 3.16, 10.0, 31.6, 100, 316, 1000 mV/EU, Velocity: 0.01, 0.0316, 0.10, 0.316, 1.00, 3.16, 10.0, 31.6, 100, 316, 1000 mV/EU, Displacement: 0.10, 0.316, 1.00, 3.16, 10.0, 31.6, 100, 316, 1000 mV/EU
Other Function ·Output level indicator: Turns on in green at -10 dB/F.S., blinks in red at F.S. over. ·Condition memory: The measurement conditions are stored even though the power is OFF. ·Condition lock: Malfunction prevention key
Power Requirement 10 V to 15 VDC * AC 100 V: available by AC adapter (sold separately)
Current Consumption 120 mA or less (When the value of 1.00 is shown at displayed device)
Unit Connection Up to 6 units for one AC adaptor
Outer Dimensions 28 (W) × 121 (H) × 194 (D) mm (not included protruded section)
Weight Approximately 510 g
Working Environment -10℃ to + 50℃, 90 % RH or less (with no condensation)
Accessories Joint cable, stabilizer, connecting metal
Options PS-P20022C(PE1821078) AC adapter

Notes

There are no additional notes for this product.